TÁPKÁBEL 4X6MM2 0.6/1kV
For transmission and distribution of electric power at construction of
distribution networks and installations with nominal voltage U0/U - 0.6/1kV and
frequency of 50 Hz. Suitable for fixed outdoor laying or indoors, in cable
ducts, tunnels, shafts, excavations. On request for UV and weather resistance,
the cable is designed with appropriate sheath resistance. Technical
characteristics: - Manufactured according to BDS 16291-85 - Rated voltage: U0/U
- 0.6/1kV - Test voltage: - AC: 4kV/50 Hz. - DC: 12kV - Maximum conductor
temperature: +70°C - Maximum conductor temperature at short circuit for 5 sec:
+160°C - Ambient temperature: -30°C to +50°C - Minimum temperature during
unstallation: -5°C - Minimum bending radius during installation: 10D - D - cable
height - Flame test: flame retardant BDS IEC 332-1 - Sheath colour: gray, black
Construction: - Copper conductors - Flexibility class: - Multi-core cable with
cross-section from 1mm˛ to 16mm˛ - class 1 according to IEC 228 - Multi-core
cable with cross-section from 16mm˛ to 25mm˛ - class 2 according to IEC 228 -
Single-core cable with cross-section from 16mm˛ to 95mm˛ - class 2 according to
IEC 228 - Insulation: PVC - Sheath: PVC - The cable is designed WITH or WITHOUT
filling Description of wires shape: - RE - solid round - RM - multi-core round -
SE - solid sector - SM - multi-core sector - RMV - multi-core round compacted
distribution networks and installations with nominal voltage U0/U - 0.6/1kV and
frequency of 50 Hz. Suitable for fixed outdoor laying or indoors, in cable
ducts, tunnels, shafts, excavations. On request for UV and weather resistance,
the cable is designed with appropriate sheath resistance. Technical
characteristics: - Manufactured according to BDS 16291-85 - Rated voltage: U0/U
- 0.6/1kV - Test voltage: - AC: 4kV/50 Hz. - DC: 12kV - Maximum conductor
temperature: +70°C - Maximum conductor temperature at short circuit for 5 sec:
+160°C - Ambient temperature: -30°C to +50°C - Minimum temperature during
unstallation: -5°C - Minimum bending radius during installation: 10D - D - cable
height - Flame test: flame retardant BDS IEC 332-1 - Sheath colour: gray, black
Construction: - Copper conductors - Flexibility class: - Multi-core cable with
cross-section from 1mm˛ to 16mm˛ - class 1 according to IEC 228 - Multi-core
cable with cross-section from 16mm˛ to 25mm˛ - class 2 according to IEC 228 -
Single-core cable with cross-section from 16mm˛ to 95mm˛ - class 2 according to
IEC 228 - Insulation: PVC - Sheath: PVC - The cable is designed WITH or WITHOUT
filling Description of wires shape: - RE - solid round - RM - multi-core round -
SE - solid sector - SM - multi-core sector - RMV - multi-core round compacted
Adatlap
Ár: | 2.060 Ft |
Termék: | Lámpa |
Feladás dátuma: | 2024.11.14 |
Eddig megtekintették 0 alkalommal |
A hirdető adatai
Bútorok rovaton belül a(z) "TÁPKÁBEL 4X6MM2 0.6/1kV" című hirdetést látja. (fent)